उत्पाद विवरण
(Regular Model) :-
| Make | "BIOLINE |
| HSN Code | 8419 |
| Certification | CE Certification |
| Construction | Vertical double walled cylindrical design, has single chamber for Steam & water ï ï ï Lid fitting Pressure gauge 0-30 PSI, safety spring loaded Pressure valve, steam Release valve. |
| Features | Foot lifting arrangement is provided in 121C/D/E/F/G |
| Basket | S. S. Rod Basket |
| Safety | Safety high pressure release valve |
| Vacuum Breaker | Vacuum breaker & self-purging system |
| Supply | 230V AC, Single Phase, 50Hz |
| SPECIFICATIONS : |
|
| Standard Model | Inside S.S. 304 mirror finish. Outer SS 304 mirror finish. |
| GMP Model | Inside S.S. 316 mirror finish. Outer SS 304 mirror finish. |
| Temp. Range | 121oc to 125oc at 15 PSI pressure 121oc to 135oc at 30 PSI pressure ( Pls ask for ETP series model ) |
| Pressure Range | 15 to 22 PSI, factory set at 15 PSI |
| Models | Capacity Liters | Internal size Dia. x Ht. cm | Rating (KW) |
| BLAR-22 A | 22 | 25 x 45 | 1.5 |
| BLAR-35 B | 35 | 30 x 50 | 2.0 |
| BLAR-53 C | 53 | 35 x 55 | 3.0 |
| BLAR-95 D | 95 | 45 x 60 | 4.0 |
| BLAR-120 E | 119 | 45 x 75 | 4.5 |
| BLAR-180F | 178 | 55 x 75 | 6.0 |
| BLAR-200 G | 200 | 22 X 36 | 6.0 |
Superior Sterilization PerformanceDesigned for efficiency in hospitals, laboratories, and pharma settings, this vertical autoclave offers precise steam sterilization. The combination of advanced insulation and pressure control ensures uniform and effective treatment of instruments and materials, making it ideal for critical applications.
Enhanced Safety and ConvenienceUser safety is a priority with built-in automatic pressure release, low water cut-off system, and secure pressure-locking lid. The device features clear water level indicators and a pressure gauge, while caster wheels allow easy relocation within your workspace.
Robust and Durable ConstructionManufactured with corrosion-resistant Stainless Steel 304/316 and a mirror finish, the autoclave is built to last. The double wall design, nickel-plated copper heater, and silicone/neoprene door gasket contribute to leak-proof, consistent operation, even with frequent use.
FAQ's of Vertical Autoclave:
Q: How do you operate the vertical autoclave for sterilizing laboratory instruments?
A: To use the vertical autoclave, fill it manually with water up to the indicated level, load the items to be sterilized, and securely close the pressure-locking lid. Set the temperature and time via the PID controller (digital models) or adjust as necessary for analog versions. Start the cycle; the autoclave automatically controls temperature and pressure, then cuts off and releases pressure safely after completion.
Q: What materials can be sterilized in this autoclave?
A: This vertical autoclave is suitable for sterilizing surgical instruments, laboratory glassware, culture media, and even medical waste. Its chamber material, made from Stainless Steel 304/316, ensures compatibility with a wide range of items commonly used in hospitals, laboratories, research, and pharmaceutical environments.
Q: When should routine maintenance be performed on the autoclave?
A: Routine maintenance is recommended after every batch for cleaning and monthly for thorough inspection. Check the gasket seal, pressure release valve, and heater for wear, and descale the chamber as required, depending on usage frequency and water quality.
Q: Where is this autoclave typically used?
A: The autoclave is widely used in hospitals, laboratories, research centers, and pharmaceutical industries throughout India. Its design and features cater to both clinical and scientific sterilization requirements.
Q: What is the process for ensuring safety during autoclave operation?
A: Safety is maintained through multiple features: the pressure-locking lid with a safety pin prevents unintentional opening, automatic pressure release valves control excess pressure, and a low water cut-off system protects the heater. Users should also verify water levels and monitor pressure gauges throughout the cycle.
Q: What are the benefits of using a double wall insulated autoclave with glass wool insulation?
A: The double wall construction with glass wool insulation ensures minimal heat loss, reducing energy consumption while maintaining stable sterilization temperatures. This design enhances both efficiency and safety during operation.